Medline Disposable Neonatal Vinyl BP Cuffs with Bayonet Connector

Manufacturer: MEDLINE

Medline Disposable Neonatal Vinyl BP Cuffs with Bayonet Connector

Manufacturer: MEDLINE

  • PVC, single-patient-use blood pressure cuffs feature rounded corners and finished edges for optimal comfort
  • Hook-and-loop closures help ensure a lasting and snug fit for patients
  • Meet the American Heart Association recommendations for accuracy
More about this item

UOM
ItemDescriptionItem DescriptionUOM
MDS9741HPV
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 110/BG
MDS9742HPV
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 210/BG
MDS9742HPVH
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 21 EA
MDS9743HPV Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 310/BG
MDS9743HPVH
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 31 EA
MDS9744HPV Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 410/BG
MDS9744HPVH
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 41 EA
MDS9745HPV
View Details
Neonatal Vinyl Single-Patient BP Cuff with Bayonet, Neonatal Size 510/BG
More about this item

Do you know the real costs of your BP Cuffs?

Research shows that reusable BP cuffs frequently carry live bacteria. The cost both financially and to your patient’s health can be high.
The good news: switch to our disposable cuffs and help reduce cross contamination.

The disposable difference: safety and simplicity.

Our disposable blood pressure cuffs are beneficial for your patients and more efficient for your caregivers. Here’s how:

Standardize and simplify your BP system

Streamline and adapt your organization so that only one type of connector is needed with our Standardization Program.
We partner with you every step of the way—from assessing your inventory and cross-referencing products,
to a full conversion that includes:

Free adapters

Installation of adapters

In-service for your staff

Cuffs for your facility

Talk to your Medline Representative about standardizing your blood pressure system today.

Troubleshooting FAQs for Medline Blood Pressure Cuffs

These cuffs are giving inaccurate readings.

  • Medline cuffs are tested to all of the same standards as other leading manufacturers including 1) air leakage testing, 2) dimensional testing, 3) 1,000 inflations cycle testing, and 4) maximum pressure testing.
  • The most common issue we see where clinicians are concerned about accuracy is due to sizing. It is important to note that the index line must fall within the range finder box on the BP cuff to ensure that the cuff is the right size for that patient.
  • If issues persist, change out the adapter on the cord. Then try testing the cuff on a different machine to see if it is an issue with the machine, the patient, or the cuff. It is important to isolate and eliminate each variable to determine the issue.

These adapters are breaking.

  • It is to be expected that there will be a percentage of adapters that break post-conversion, as users get used to the new connection style, especially when going from a push button connector to the HP/bayonet style.
  • Do not twist the sheath on the adapter. The sheath should be pulled back when disconnecting the cuff.
  • Do not hold the sheath on the adapter when inserting the cuff. Hold the end of the adapter or the tubing when inserting the cuff, so as to not lock the sheath in the upward position.
  • We leave extra adapters with BioMed, and they can assist with swapping out the adapters if needed once the Medline team is no longer on site.